MEASUREMENTS AND DOCUMENTATION
Measurements & documentation
Every RedLab model has been tested by independent laboratories. Light output was measured with a spectrometer and, for comparison, with a Solarmeter, with the original measurement photos included.
Light output at measuring distance
Solid: measured · Dashed: calculated (red and NIR in a 1 to 3 ratio)
At 15 cm, combined: spectrometer 100.1 mW/cm² · Solarmeter 217.5 mW/cm²
Many brands measure with a Solarmeter. It is calibrated for sunlight and reads higher on LED panels. We show both: the Solarmeter for comparison, the spectrometer for calculating.
View the measurement report with the original measurement photos (PDF) →
Safety and documents
With the CE mark we declare that the panel meets the European requirements for electrical safety, electromagnetic compatibility and hazardous substances. We support this with test reports from independent laboratories.
CE · DoC
EU declaration of conformity
Our declaration that the panels meet the European requirements. Applies to One, Pro and Max.
Measurement report
Light output and EMF
Spectrometer, Solarmeter and EMF measurements, with the original measurement photos.
Tested to European standards
- Tested
LVD
Electrical safety
EN 60598-1 · EN 60598-2-4 · EN 62031 · IEC/TR 62778
- Tested
EMC
Electromagnetic compatibility
EN IEC 55015 · EN 61547 · EN IEC 61000-3-2 · EN 61000-3-3
- Tested
EMF
Electromagnetic fields
EN 62493
- Tested
RoHS
Hazardous substances
(EU) 2015/863 · EN 62321
- Tested
RED
Bluetooth and radio equipment
EN 300 328 · EN 301 489-17 · EN 62311
We will send you the full test reports on request.
Request report →Electricity cost per session
480 W for 10 minutes is 0.08 kWh. At an electricity price of 0.30 euro per kWh, one session with the RedLab Pro costs about 2.4 cents.
Nominal power as stated by the manufacturer.
Frequently asked questions
Why do other brands state higher values?
Often they measured with a Solarmeter, or right in front of the LED. A Solarmeter is calibrated for sunlight and reads higher on LED panels: on the Pro it gives ±218 mW/cm², the spectrometer 100. We calculate with the spectrometer and always state the measuring method.
How much EMF does the panel emit?
Very little. Right against the panel we measured at most 0.46 µT, at 15 cm 0.00 µT. The European reference value is 100 µT.
Can I see the test reports?
Yes. You can download the declaration of conformity and the measurement report above. We will send you the full test reports on request.
What is the difference between measured and calculated?
Measured means determined with a measuring instrument, such as the light output at 15, 30 and 45 cm. Calculated means derived from those measurements, such as the split between red and NIR in combined mode. The chart shows which of the two each value is.
Question not listed? Get in touch →